CONTROLWARE COMMUNICATIONS SYSTEMS, INC. CITAM Card Type ISDN TA Chipset Unidentified ISDN Transfer Rate 56Kbps x 2/64Kbps x 2 ISDN Protocol V.110, X.75 Switch Type 1TR6, 5ESS, DMS100, DSS1, NI-1 Data Bus Serial [Image] CONNECTIONS Function Label Function Label SELECT button BT1 ISDN S/T interface CN1 ENTER button BT2 LED display LED RESET button BT3 Header to interface W1A board W1B Note: Either CN1 or the ISDN interface on the installed interface board may be used, but not both. USER CONFIGURABLE SETTINGS Setting Label Position Configuration may be changed via interface S1/1 Off or front panel Configuration may be changed via front panel S1/1 On supervisor only ISDN connects with standard dialing S1/2 Off ISDN connects with S0FV (leased-line) S1/2 On 1TR6 Service Indicator set for data S1/3 Off transmission 1TR6 Service Indicator set for X.21 services S1/3 On TA operates in synchronous mode S1/4 Off TA operates in asynchronous mode S1/4 On Factory configured - do not alter S1/5 N/A (synchronous mode) USER CONFIGURABLE SETTINGS (CON’T) Setting Label Position AT command set enabled (asynchronous mode) S1/8 On V.25bis command set enabled (asynchronous mode) S1/8 Off X.21 command set enabled (synchronous mode) S1/8 On V.25bis command set enabled (synchronous mode) S1/8 Off Factory configured - do not alter S2/1 On CD signal forced high S2/6 Off CD signal high when connection is synchronized S2/6 On DSR signal forced high S2/7 Off DSR signal high when connection is synchronized S2/7 On Unit is a table-top version S2/8 Off Unit is a rack mount version s2/8 On DATA FORMAT SELECTION (ASYNCHRONOUS MODE) Setting S1/5 S1/6 S1/7 7 data bits, no parity, 1 Off On On stop bit 7 data bits, even parity, On On On 1 stop bit 8 data bits, no parity, 1 On On Off stop bit 8 data bits, even parity, Off Off On 1 stop bit 8 data bits, odd parity, On Off On 1 stop bit 8 data bits, no parity, 2 Off Off Off stop bits 8 data bits, even parity, On Off Off 2 stop bits 8 data bits, odd parity, Off On Off 2 stop bits DATA FORMAT SELECTION (SYNCHRONOUS MODE) Setting S1/6 S1/7 ASCII character set, BSC On On encoding ASCII character set, HDLC Off On encoding EBCDIC character set, BSC On Off encoding EBCDIC character set, HDLC Off Off encoding LINE SPEED Setting S2/2 S2/3 S2/4 S2/5 300bps Off On Off On 600bps On Off Off On 1200bps Off Off Off On 2400bps On On On Off 4800bps Off On On Off 9600bps On Off On Off 19.2Kbps Off Off On Off 38.4Kbps On On Off Off 48Kbps Off On Off Off 56Kbps On Off Off Off 64Kbps Off Off Off Off Note: Asynchronous speeds may range from 300bps to 38.4Kbps, while synchronous speeds may range from 1200bps to 64Kbps. SUBADDRESS SELECTION Setting S3 EAZ 1 Position 1 EAZ 2 Position 2 EAZ 3 Position 3 EAZ 4 Position 4 EAZ 5 Position 5 EAZ 6 Position 6 EAZ 7 Position 7 EAZ 8 Position 8 TA is part of hunt group Position 0 Note: When adapter is set for leased-line mode, the EAZ must be set to 2. DIAGNOSTIC LED(S) LED Color Status Condition S0 Yellow On ISDN connection is active S0 Yellow Blinking ISDN connection has been made but is not active S0 Yellow Off ISDN is not connected P1 Green On Port 1 is connected to ISDN P1 Green Blinking Port 1 has received an ISDN call but has not connected P1 Green Off Port 1 is not connected to ISDN P2 Green On Port 2 is connected to ISDN P2 Green Blinking Port 2 has received an ISDN call but has not connected P2 Green Off Port 2 is not connected to ISDN Note: P2 will have no function on models with only one port. [Image] CONNECTIONS Function Label Function Label Supervisor port CN1 DC power in CN4 ISDN S/T interface CN2 Header to main board W1A W1B X.21 serial port CN3 USER CONFIGURABLE SETTINGS Setting Label Position Signal ground not connected to chassis ground P31 Open Signal ground connected to chassis ground P31 Closed RECEIVER OPEN CIRCUIT FAILSAFE Setting P28 R3 Enabled Not installed Installed Disabled Installed Not installed [Image] CONNECTIONS Function Label Function Label Supervisor port CN1 X.21 serial port 2 CN4 ISDN S/T interface CN2 DC power in CN5 X.21 serial port 1 CN3 Header to main board W1A W1B USER CONFIGURABLE SETTINGS Setting Label Position Signal ground not connected to chassis ground P31 Open Signal ground connected to chassis ground P31 Closed PORT 1 RECEIVER OPEN CIRCUIT FAILSAFE Setting P16 R4 Enabled Not installed Installed Disabled Installed Not installed PORT 2 RECEIVER OPEN CIRCUIT FAILSAFE Setting P17 R5 Enabled Not installed Installed Disabled Installed Not installed [Image] CONNECTIONS Function Label Function Label Supervisor port CN1 DC power in CN4 ISDN S/T interface CN2 Header to main board W1A W1B V.24 serial port CN3 USER CONFIGURABLE SETTINGS Setting Label Position Signal ground not connected to chassis ground P32 Open Signal ground connected to chassis ground P32 Closed RECEIVER OPEN CIRCUIT FAILSAFE Setting P1 R4 Enabled Not installed Installed Disabled Installed Not installed [Image] CONNECTIONS Function Label Function Label Supervisor port CN1 V.24 serial port 1 via CN4 DB-26 port ISDN S/T interface CN2 DC power in CN5 V.24 serial port 2 via CN3 Header to main board W1B DB-26 port W1A Note: Standard V.24 serial ports are provided on included adapter cables. USER CONFIGURABLE SETTINGS Setting Label Position Signal ground not connected to chassis ground P33 Open Signal ground connected to chassis ground P33 Closed PORT 1 RECEIVER OPEN CIRCUIT FAILSAFE Setting P1 R3 Enabled Not installed Installed Disabled Installed Not installed PORT 2 RECEIVER OPEN CIRCUIT FAILSAFE Setting P2 R4 Enabled Not installed Installed Disabled Installed Not installed [Image] CONNECTIONS Function Label Function Label Supervisor port CN1 DC power in CN4 ISDN S/T interface CN2 Header to main board W1A W1B V.35 serial port CN3 USER CONFIGURABLE SETTINGS Setting Label Position Signal ground not connected to chassis ground P32 Open Signal ground connected to chassis ground P32 Closed [Image] CONNECTIONS Function Label Function Label Supervisor port CN1 V.35 serial port 1 via CN4 DB-26 port ISDN S/T interface CN2 DC power in CN5 V.35 serial port 2 via CN3 Header to main board W1B DB-26 port W1A Note: Standard V.35 serial ports are provided on included adapter cables. USER CONFIGURABLE SETTINGS Setting Label Position Signal ground not connected to chassis ground P32 Closed Signal ground connected to chassis ground P32 Open SUPPORTED STANDARD COMMANDS Basic AT Commands +++, A/ A, E, H, O, Q, V, X, Z &D, &F, &V, &W, &Z %I S-Registers S0, S1, S2, S3, S4, S5 V.25bis Commands CIC, CRI, CRS, DIC, PRN Note: See MHI help file for complete information. UNIDENTIFIED COMMANDS Command Default %L 0 %M 0 Proprietary AT Command Set ACCESS TYPE Type: Configuration Format: AT [cmds] %Kn [cmds] Description: Selects the type of access for this ISDN line. Command Function %K1 Line is intermittent dial-up. %K2 Line is semi-permanent dial-up. %K3 Line is time-link dial-up. ASYNC/SYNC MODE Type: Configuration Format: AT [cmds] &Mn [cmds] Description: Selects whether the adapter is operating in asynchronous or synchronous mode. Command Function &M0 Asynchronous mode selected. &M1 Asynchronous command mode, synchronous data mode at 600bps. &M2 Asynchronous command mode, synchronous data mode at 1200bps. &M3 Asynchronous command mode, synchronous data mode at 2400bps. &M4 Asynchronous command mode, synchronous data mode at 4800bps. &M5 Asynchronous command mode, synchronous data mode at 9600bps. &M6 Asynchronous command mode, synchronous data mode at 19.2Kbps. &M7 Asynchronous command mode, synchronous data mode at 38.4Kbps. &M8 Asynchronous command mode, synchronous data mode at 48Kbps. &M9 Asynchronous command mode, synchronous data mode at 56Kbps. &M10 Asynchronous command mode, synchronous data mode at 64Kbps. &M11 Synchronous data mode at 64Kbps with byte timing. &M13 Synchronous data mode at 128Kbps. CALLBACK DELAY Type: Configuration Format: AT [cmds] %H=n [cmds] Default: Unidentified Range: 0 - 255 Unit: 1 second Description: Sets the amount of time that the adapter will wait after a call disconnects before initiating a callback sequence. CALLBACK MODE Type: Configuration Format: AT [cmds] %Gn [cmds] Description: Selects when the adapter will call back an incoming call. Command Function %G0 Neither initiate nor allow callback requests. %G1 Do not initiate callbacks but allow requests. %G2 Initiate callbacks but do not allow requests. %G3 Initiate callbacks and allow requests. CALL BUNDLING SOURCE Type: Configuration Format: AT [cmds] %Jn [cmds] Description: Selects which stored number the modem will dial for the B2 channel when attempting call bundling. Executing %J0 will use the same number as was dialed for the B1 channel. CTS SIGNAL Type: Configuration Format: AT [cmds] &Rn [cmds] Description: Controls the behaviour of the CTS signal. Command Function &R0 CTS follows RTS. &R1 CTS forced high. &R2 CTS controlled by remote; high when connection is made at 48Kbps or less. DATA FORMAT Type: Configuration Format: AT [cmds] %Nn [cmds] Description: Selects the format of the data from the serial port. Command Function %N0 7 data bits, no parity, 1 stop bit. %N1 7 data bits, even parity, 1 stop bit. %N2 8 data bits, odd parity, 1 stop bit. %N3 8 data bits, even parity, 1 stop bit. %N4 8 data bits, no parity, 1 stop bit. %N5 8 data bits, odd parity, 2 stop bits. %N6 8 data bits, even parity, 2 stop bits. %N7 8 data bits, no parity, 2 stop bits. DCD SIGNAL Type: Configuration Format: AT [cmds] &Cn [cmds] Description: Controls the behaviour of the DCD signal. Command Function &C0 DCD high when call is synchronized. &C1 DCD forced high. &C2 DCD controlled by remote; high when connection is made at more than 48Kbps. DISPLAY INFORMATION Type: Immediate Format: AT [cmds] In [cmds] Description: Displays information requested about the adapter. Command Function I Displays complete identification. I0 Displays information about the control firmware. I1 Displays information about the ISDN firmware. I2 Displays the version of the hardware. I3 Displays information about the interface board. DISPLAY STATUS Type: Immediate Format: AT [cmds] %Sn [cmds] Description: Displays the status of the indicated part of the adapter. Command Function %S Display all information. %S0 Display port status. %S1 Display S0 status. %S2 Display last ISDN error code in hex. %S3 Display SPID 1. %S4 Display SPID 2. DSR SIGNAL Type: Configuration Format: AT [cmds] &Sn [cmds] Description: Controls the behaviour of the DSR signal. Command Function &S0 DSR high when connection is successful. &S1 DSR forced high. &S2 DSR controlled by remote; high when connection is made at more than 48Kbps. &S3 DSR high when connection is synchronized. ISDN B-CHANNEL MAPPING Type: Configuration Format: AT [cmds] %Qn [cmds] Description: Selects how the adapter will map the B-channel subaddresses. Command Function %Q0 B-channel mapping disabled. %Q1 B-channel mapping enabled. LOCAL SERIAL PORT SPEED Type: Configuration Format: AT [cmds] %Rn [cmds] Description: Selects what speed the local serial port is operating at in asynchronous mode. Command Function %R0 Set speed to 300bps. %R1 Set speed to 600bps. %R2 Set speed to 1200bps. %R3 Set speed to 2400bps. %R4 Set speed to 4800bps. %R5 Set speed to 9600bps. %R6 Set speed to 19.2Kbps. %R7 Set speed to 38.4Kbps. MATCH IN-BAND SPEED Type: Configuration Format: AT [cmds] %An [cmds] Description: Selects whether the adapter may switch to match the in-band speed of the connection. Note: This command has no effect in asynchronous mode. Command Function %A0 Adapter may switch to lower speed. %A1 Adapter may not switch speed. %A2 Adapter may switch to higher speed. %A3 Adapter may switch to any speed. MATCH BEARER SPEED Type: Configuration Format: AT [cmds] %Bn [cmds] Description: Selects whether the adapter may switch to match the bearer speed of the connection. Note: This command has no effect in asynchronous mode. Command Function %B0 Adapter may switch to lower speed. %B1 Bearer speed matching disabled. %B2 Adapter may switch to higher speed. %B3 Adapter may switch to any speed. %B4 Bearer speed matching enabled. PASSWORD CHECKING Type: Configuration Format: AT [cmds] %Dn [cmds] Description: Selects when the adapter will require a password for configuration changes. Command Function %D0 Require password for remote configuration changes only. %D1 Require password for all configuration changes. PASSWORD SET Type: Configuration Format: AT %C=xxxx Description: Sets the password to a case-sensitive string of up to ten characters. If no string is entered the password is returned to its default. PROTOCOL Type: Register Format: AT [cmds] S8=n [cmds] Description: Selects the bit rate adaptation protocol the adapter will use. Command Function S8=0 Adapter will use X.30. S8=1 Adapter will use V.110. SERVICE INDICATOR Type: Register Format: AT [cmds] S6=n [cmds] Description: Sets the 1TR6 Service Indicator. Command Function S6=3 1TR6 Service Indicator set for data transmission. S6=7 1TR6 Service Indicator set for X.21 services. SUBADDRESS Type: Register Format: AT [cmds] S7=n [cmds] Description: Sets the subaddress to a value from 1 to 8. SUBADDRESS COPYING Type: Configuration Format: AT [cmds] %En [cmds] Description: Selects whether the adapter will copy the subaddress to the call number. Command Function %E0 Subaddress copying disabled. %E1 Subaddress copying enabled. SUBADDRESS - SETUP Type: Configuration Format: AT [cmds] %Pn [cmds] Description: Selects which subaddress the adapter sends during call setup. Command Function %P0 Adapter sends remote port subaddress. %P1 Adapter sends local port subaddress. SUBADDRESS SOURCE Type: Configuration Format: AT [cmds] %On [cmds] Description: Selects the source of the subaddress sent to the remote system. Command Function %O0 Taken from call number string. %O1 Global call sent in-band. %O2 Stored port subaddress sent in-band. %O3 Stored port subaddress sent in-band and during call setup. SWITCH TYPE Type: Configuration Format: AT [cmds] %Fn [cmds] Description: Selects the switch type the adapter is connected to. Command Function %F0 Adapter is connected to National NI-1 switch. %F1 Adapter is connected to AT&T 5E6 switch. %F2 Adapter is connected to AT&T 5E8 switch. %F3 Adapter is connected to Northern Telecom DMS-100 switch. Proprietary V.25bis Command Set CALL REQUESTED NUMBER Type: Immediate Format: CRN<#> Description: Dials the number given; it will ignore spaces and hyphens in the string; if the string is more than fifty characters long, a result of INV will be returned. Command Function CRN<#>*n Dials the number indicated and requests subaddress n. CRN<#>/n Dials the number indicated and requests subaddress n. CTS SIGNAL Type: Configuration Format: PRO4;n Description: Controls the behaviour of the CTS signal. Command Function PRO4;0 CTS follows RTS. PRO4;1 CTS forced high. PRO4;2 CTS controlled by remote; high when connection is made at 48Kbps or less. DCD SIGNAL Type: Configuration Format: PRO6;n Description: Controls the behaviour of the DCD signal. Command Function PRO6;0 DCD high when call is synchronized. PRO6;1 DCD forced high. PRO6;2 DCD controlled by remote; high when connection is made at more than 48Kbps. DISPLAY COMMAND SETTING Type: Immediate Format: RLO n Description: Displays the setting of the indicated option set with PROn; the adapter will respond with LSOn;a where a is the setting. Two values may be displayed that may not be set with PROn. They are listed below. If no value is given all options are listed. Command Value Meaning RLO 8 0 Terminal is in asynchronous mode. 1 Terminal is in synchronous mode. RLO 9 3 1TR6 Service Indicator set for data transmission. 7 1TR6 Service Indicator set for X.21 services. DISPLAY STORED NUMBER Type: Immediate Format: RLN n Description: Displays the telephone number stored in memory location n. If no location is specified, all stored numbers are listed. DSR SIGNAL Type: Configuration Format: PRO5;n Description: Controls the behaviour of the DSR signal. Command Function PRO5;0 DSR high when connection is successful. PRO5;1 DSR forced high. PRO5;2 DSR controlled by remote; high when connection is made at more than 48Kbps. PRO5;3 DSR high when connection is synchronized. ECHO Type: Configuration Format: PRO2;n Description: Selects whether the modem will echo data received from the DTE back. Note: This command has no effect in synchronous mode. Command Function PRO2;0 Echo disabled. PRO2;1 Echo enabled. INCOMING CALL INFORMATION Type: Configuration Format: PRO7;n Description: Selects whether the INC message is V.25bis standard or displays extra information. Command Function PRO7;0 INC message is V.25bis standard. PRO7;1 INC message displays extra information. PROTOCOL Type: Register Format: PRO3;n Description: Selects the bit rate adaptation protocol the adapter will use. Command Function PRO3;0 Adapter will use X.30. PRO3;1 Adapter will use V.110. RESET TO SWITCH DEFAULTS Type: Immediate Format: PRO0;0 Description: Resets the configuration of the adapter to the settings of S1, S2, and S3. SUBADDRESS Type: Configuration Format: PRO1;n Description: Sets the subaddress to a value from 1 to 8.